Pardon a WLED question in the Home Assistant community, but I was unable to find a WLED community in the fediverse.

Regardless, I have this 720 LED/meter FCOB strip, which is 24v strip & I’m trying to figure out what to configure the “LED voltage (Max. current for a single LED):”

Since it’s a 20IC per meter & they claim 21watts per meter that comes out to ~1w per IC. But I’m unsure how that converts to mA like WLED is asking for.

Any advice would be greatly appreciated 🤠

  • @[email protected]
    link
    fedilink
    English
    61 month ago

    If i’m understanding your question, what you’re looking for is Ohm’s law
    Amp = watt / volt
    1 / 24 = 0.042
    You want milliamps, so multiply by 1000 giving you 42mA per IC

    • @ApplyingAutomationOP
      link
      English
      21 month ago

      Thank you!

      I guess the second part of my question is I want to confirm that WLED says “per LED” they really mean “per IC”.

      • @[email protected]
        link
        fedilink
        English
        41 month ago

        Yes that’s correct. Same goes for the normal WS2811 strip lights which are addressable every 3 LEDs.

      • @[email protected]
        link
        fedilink
        English
        31 month ago

        Yes, they understand an led as a thing they can control. I have an analog strip that is one LED

      • @[email protected]
        link
        fedilink
        English
        21 month ago

        I’m happy to help.

        I don’t know much about WLED, but from the other comments here it would appear so. And i think it’s also what makes the most sense.

  • @[email protected]
    link
    fedilink
    English
    31 month ago

    It bothers me that the setting is called LED voltage but refers to current. But at least it refers to current, because controlling the voltage to power an LED is a recipe for a burnt out LED.

    • Courant d'air 🍃
      link
      fedilink
      English
      21 month ago

      Bothers me as well, time to contribute and open an issue! I’ve never installed WLED so I won’t be able to describe where this setting is and give more information but I invite you or OP to do it

    • @[email protected]
      link
      fedilink
      English
      11 month ago

      This is a weird setting that must be in some brand new release because I’ve been using WLED for years and it’s always just been a current limiter for the entire strip. Perhaps it has something to do with OP using COB lights as I’ve only ever used it for standard strip lights like 5050 WS2812B or 5050 WS2815.

      • @[email protected]
        link
        fedilink
        English
        21 month ago

        It’s near the current limiter setting, it’s in 0.14.0-0.14.4 at least (Sample size two boards, one that needs updating). It’s how wled estimates how much current each LED takes