• @[email protected]
      link
      fedilink
      333 days ago

      I’m not OP, but when I did this, it was so allow me to run a pipe cleaning tool in each direction to clear blockages.

      • @BellOP
        link
        82 days ago

        Exactly this

  • IninewCrow
    link
    fedilink
    English
    213 days ago

    That’s not a dull man that is able to do a job like that … nice work!

    • @[email protected]
      link
      fedilink
      133 days ago

      permission was granted by the surrounding soil, neither did it intervene, nor did it stand its “ground” ;-)

    • @[email protected]
      link
      fedilink
      83 days ago

      Depends on the state and jurisdiction.

      I was a health dept inspector that focused on septic systems and a homeowner installing or repairing a cleanout would not be something we would require a permit. It would be considered a minor repair or plumbing work on the building sewer unrelated to the functionality of the disposal system–just needs to be watertight.

      And the regulations in my state are some of the nations most stringent on this kind of stuff.

    • @BellOP
      link
      22 days ago

      Exactly. Well kinda because it’s still shitty work even with the clean out.

  • @David_Eight
    link
    83 days ago

    Shouldn’t you use a “Y fitting” at the bottom?

    • @Sludgeyy
      link
      53 days ago

      This tee fitting is designed to be snaked both ways

      A wye fitting is designed to be snaked one direction

      For example, you’d use a wye fitting after a gutter. If you’re going to snake it, it will not be in the direction of the gutter. You’re not sending the snake up the gutter. The wye would allow you to snake the portion of pipe you need easier.**

      If this was in the middle of a long sewer pipe with no other clean outs near by. Then the tee is probably the better choice.

      • @grue
        link
        English
        32 days ago

        The issue is whether the crossbar of the tee is flat along the bottom or not (I can’t tell from the pic). If not, it’s going to risk causing a clog itself.

        • @Sludgeyy
          link
          22 days ago

          That was my thought, but apparently, this tee is designed exactly for this purpose. $40 for just the tee.

  • @DampCanary
    link
    23 days ago

    what fi is that pipe? Looks like black pvc water pipe.
    I expected fi 110 for sewers.

    • @ikidd
      link
      English
      22 days ago

      Its cast iron. And I assume its somewhere warm and dry if its that close to the surface.

      • @BellOP
        link
        42 days ago

        Cast iron, at least 60 years old, could be 100. And it’s in North Florida.

  • Optional
    link
    13 days ago

    What about the ballcock?!

    *snkk*