It’s my first house and I was hesitant to drill holes in it, but things came out okay.

Not only is the faceplate level, but it’s also pretty much level with the existing electric outlet faceplate!

  • @keckbug
    link
    53 days ago

    Hey, really great work on this!

    I used to run low voltage wiring professionally, and that looks pretty great. One tip for next time: You can use clues such as that nail to help connect what you see “up top” with where you’re looking down below. The wall itself will have a “bottom plate”, a 2x4 laid flat horizontally across the floor, and it’s nailed through the floor and you’ll often see nails such as that one exactly where the wall is.

    There’s no 100% hard and fast rules, but you can also look for the presence of other holes for things like electrical wire, or HVAC vents as clues too. One really important thing to remember is that 95% of the time, electrical outlets will be mounted directly to a stud. You can knock on the wall or remove the cover plate and use a small flat screwdriver to probe around and determine which side of the outlet is against the stud, and which is in an open wall space. That helps you plan where to drill down below to give you the best shot at hitting your intended location. If you remember that studs are generally 16” apart, it can help you visualize that section of the wall.

    Avoid running wires close to windows, doors, or corners. Studs can do some really funky things in those spaces, and you’ll have a much harder time.

    • LostAndSmelly
      link
      English
      23 days ago

      That’s great advice. I would also like to add that communications cable is usually UTP or unshielded twisted pair and subject to interface. It is best to run it 24" from power cables when parallel and to cross power cables at right angles.

      • @keckbug
        link
        2
        edit-2
        3 days ago

        Totally accurate advice, but I haven’t usually seen it be terribly important in a residential setting because

        1. The distances are relatively short
        2. The cables are often overspecced (ie, simple gigabit over 50ft of cat-6)
        3. There’s often only really one viable path due to other constraints

        They’re important considerations for sure, but I haven’t generally bumped up against them in the real world in typical houses.

        • LostAndSmelly
          link
          English
          13 days ago

          Those are solid points. I don’t do any residential work and I suppose that shows.