In my kitchen I have a flushmount light with an integrated led. I put in an LED dimmer on the switch and all is working well.

However, I had to replace it way sooner than I was expecting. Is there a possibly that the dimmer is hard on it?

I have the exact same one on another non-dimmer switch that is still running fine. That said the other one gets much less use so it could just be that.

  • @stealthnerd
    link
    1
    edit-2
    1 year ago

    LED’s can be very particular about their dimmer. Unfortunately it’s not enough just to go to the store and pick up a dimmer switch that claims compatability with LED’s .

    Fortunately most LED fixtures/bulbs come with a list of recommended dimmers, at least if you stick with larger brands and not cheap LED’s from Amazon.

    I know a few in my house require ELV dimmers and those sell to the tune of $50/ switch whereas others work fine with a $10 MLV.

    Meanwhile my under cabinet lights explicity state not to use an ELV dimmer and to only use MLV or risk damaging the unit.