Just figured I’d add some content here so I’m just going through old photos/videos.

  • @Knasen
    link
    2
    edit-2
    11 months ago

    May I ask for what reason/purpose the two pipes on the right are not connected end to end but rather have endstops and then are connected a bit in?

    • @BigtiddygothgranyOP
      link
      111 months ago

      Are you talking about the ones that are on a loop? That are tied into the rightmost valve? If so those are for a body spray system.

      • @Knasen
        link
        311 months ago

        No, was thinking about these joints and endpoints.

        • @BigtiddygothgranyOP
          link
          311 months ago

          Ahh those are just air chambers which are still required in most of the locations that I work.

            • @BigtiddygothgranyOP
              link
              111 months ago

              The ones that are in the pictures of the article you sent are actually effective, the ones that we use that’s acceptable by code still is just a 12 inch pipe with a cap. They don’t really work though because over time the air pockets full up with water so they basically become useless.