Feel free to roast me if this is idiotic. Thank you!

  • @Huxleywaswrite
    link
    English
    121 year ago

    As long as the whole wire run is that neat, the soffit probably isn’t anything to be concerned about, but personally i would run a cable support on the frame and put the wire in that, instead of how you have it here.

    Water doesn’t just mean submerged. Water comes from humidity, condensation and dew daily. If it’s not rated for that then it will likely fail after some time. It’s being used in a way it wasn’t designed to be, that has an effect on the lifespan of a device. To mitigate that you could put it inside of some type of conduit.

    I typed all of this out, and then decided to check your link for better pictures. That camera comes with ethernet waterproof cable shielding. I’m guessing that is exactly enough to go from the camera to the mounting bracket. So no, none of this cable is rated to be outdoors, this is not a safe way to install it. You either need to run conduit or penetrate the wall behind the mounting hardware and feed it through there.

    • @PogbomOP
      link
      English
      31 year ago

      Damn, this makes a lot of sense. Is there any kind of conduit you would recommend then? I think I’ve seen that anything PVC is ideal for outdoor cables. Would that also help with the condensation risks?

      • @Huxleywaswrite
        link
        English
        21 year ago

        No, pvc is not water tight at all. I’d grab some sealtight flexible conduit, nonmetallic would be fine. Just grab some one hole straps and support the conduit every 6-8 feet. It’s under your deck and you’re a homeowner, not a professional; theres no reason to try and make it straight or neat.

        You will need some sort of an enclosure to run the sealtight to. Any outdoor rated junction box should be fine, mount it as close as you can because your going to be using that ethernet watertight protector to go from the junction box to the camera itself. I’d probably just mount the camera to the enclosure cover itself and make it easy.

        • @PogbomOP
          link
          English
          21 year ago

          My god I have so much to learn. That makes a lot of sense. Thanks so much for all your help. I’ll get cracking on this in the coming days you might get a few DMs in the near future haha.

            • @PogbomOP
              link
              English
              2
              edit-2
              1 year ago

              I was gonna DM you but I figured I might as well keep it here in case it can help someone else :)

              It looks like the first few inches of cable coming out of the camera (the segment with the power/ethernet splitter) is outdoor rated. It’s just the thin extension cable and power block cable that are meant for indoors it seems.

              So what if I bought something like this?

              Being sure that it’s compatible, I could run this outdoor rated cable all the way to a junction box right beside the outlet, instead of installing conduit the whole way. Is that a crazy idea?

              • @Huxleywaswrite
                link
                English
                11 year ago

                Yeah, as long as it’s rated for outdoors you should be fine. And a little extra tape and heatshrink are always worth it in the long run.

                • @PogbomOP
                  link
                  English
                  21 year ago

                  Amazing. I wish I could pay you but I hope my thanks are enough :)