Sorry if this isn’t the right community. I’m adding blinkers to a side-by-side and I have the blinkers working. However I can’t understand how to connect the hazard switch to the blinkers without losing the blinker functionality. When I connect them it makes both blinkers go off when I try to use the blinkers. Is someone able to point me in the right direction? Thanks!

  • @kjpctechOP
    link
    English
    211 months ago

    Thanks! I think that is what I was originally trying. By adding the hazard “3” connection to both sides of the blinkers it ends up connecting them so that whether I use blinkers or hazards it’s all the same. I’m going to do some more debugging with a multimeter and see if I can understand the switch more. I’ll probably just end up getting diodes and wiring it like this diagram with diodes. Just bothering me that I might be missing something.

    • @agent_flounder
      link
      English
      2
      edit-2
      11 months ago

      Gotcha. I think diodes are the easiest solution here. Idk what they were thinking with these instructions.

      If the hazard switch was a dual pole, then you could connect the right side to one pole and the left side to the other pole and then it would only connect Left and Right when hazards are on.

      • @agent_flounder
        link
        English
        211 months ago

        With diodes:

        With dual pole hazard switch:

        • @kjpctechOP
          link
          English
          111 months ago

          Added the diodes today and it’s all working great! Thanks for helping me understand this!