Hey!

Currently doing drywall myself and I am using 6x6 cm squared timber around my outside walls.

The problem is they aren’t as stable as the other walls inside the house because of the 6x6 cm squared timbers that are about 30cm distance from each other.

I will screw my plasterboards on the squared timber and only one plasterboard, not two.

I have two pictures of what my construction looks like from far and one from close.

Maybe someone can give me advice before I install the plasterboard onto it.

The only problem I currently see is finding the subconstruction once I put the plasterboards back on. But other than that, if I find them can I install the cabinets safely?

  • @GrogonOP
    link
    3
    edit-2
    10 months ago

    So I guess I should be fine?

    I am having heart attack and panic right now.

    My construction dude told me to apply 6x6 cm squared timber for installation (electricity) and spread the about 30 cm apart from each other around the house. Once the electrician comes and installs everything and is finished I can install plasterboard onto the 6x6cm squared timber.

    I am just not sure if I can hang anything on the plasterboard that is attached to 6x6cm timber. It would be alot more stable if I could get rid of the 6x6cm timber and attach plasterboard to plywood (like the inside walls).

    At the end he said it’s for electricity only and my safety so I don’t break the vapor barrier later if I screw something into the plasterboard. So I have about 6 cm “air” before the “real” wall starts after the plywood.

    Its basically from inside to outside:

    Plasterboard -> 6x6 cm squared timber -> Plywood -> Studs -> Vapor Barrier -> Insulation (240mm wool) ->… in the end the totall wall is about 39cm thick.

    • roguetrick
      link
      fedilink
      1
      edit-2
      10 months ago

      So are the 6x6s attaching just into the plywood or are they going into something behind the plywood? Overall it sounds fine what he told you to do, but what they’re attaching to and how you do what we call “blocking” to secure them is how you determine if you can hang cabinets.

      Edit: Per your additional information, what you’re doing is fine but I’d ask him specifically about where you want to hang cabinets because you’d need to make more consideration. They put a lot more strain than thin drywall to the fasteners that are holding them up.

      • @GrogonOP
        link
        210 months ago

        I have bigger screws in those that go into a bigger piece of wood behind the plywall.

        I guess it’s the studs then. So my 6x6 cm squared timber that I am installing vertically is going into studs behind the plywall

        • roguetrick
          link
          fedilink
          110 months ago

          Yeah, that’s essentially fine. You likely can hang cabinets off of them, but I’m not a cabinet installer or a framer. I’m a nurse that used to sell building supplies. You should ask him if you need more reinforcement for your cabinets. For your drywall everything’s fine.

          • @GrogonOP
            link
            210 months ago

            Alright cool.

            Yeah well I am just a nurse too (but in germany) or else I’d not have to ask here lol.

            I sent a picture of the subconstruction to the kitchen company and they will tell me more.

            • roguetrick
              link
              fedilink
              310 months ago

              My suggestion is a oral administration etoh at this point, then.

              • @GrogonOP
                link
                310 months ago

                lol :-) I really almost sh*t my pants cause I thought the house was constructed good and suddenly everyone tells me to contact help and that I am lost.