• @Hardeehar
    link
    39 hours ago

    Real fake dooooooooooooooooorrrrrssss

  • @aeronmelon
    link
    3518 hours ago

    When the security doors are down after hours, that door allows staff to go from one side to the other. You can see the guidelines in the edges of the wall.

    The combination of building safety laws and how the floor plan was designed forced the door to be placed there instead of off to the side.

    I’ve seen this anomaly a few times.

    • @[email protected]
      link
      fedilink
      English
      514 hours ago

      Huh. I always thought those barriers were meant to be a way for people to navigate their way out when the automatic firewalls come down.

    • @Death_Equity
      link
      1118 hours ago

      While this explanation makes sense, I prefer the reality in which a business needed X number of emergency exits for the size of the space and they got the big brain move to add this bad boy to game the system and meet the criteria.

      • @[email protected]
        link
        fedilink
        2419 hours ago

        Conference rooms are built big. Like in hotels, or conference centers.
        But not everyone wants a big room if they only have 100 people in the audience. And they don’t want to pay for a room that can hold 600 people, when they are only gonna be clumped up in like 1/3 of the room or whatever.

        So conference rooms are built in a way they can be subdivided. By airwalls.
        Next time you are at a conference, look for tracks in the ceiling. Like a metal channel with a slot running through it.
        Or look for a wall made up of 1m sections.
        That’s airwall track & airwall.
        You run them along the track until they hit another bit of wall, stick an Allen key in the end of them, and wind down a soundproofing seal that also locks the wall in place. Then you run out another, and so on, until there is a wall.

        Where the track meets the actual room walls, there will be additional tracking and full height doors that allow the wall to be manoeuvred and stored

        • @jqubed
          link
          313 hours ago

          I never knew the name for those

      • @[email protected]
        link
        fedilink
        519 hours ago

        Additionally, this seems to be a permanent piece of building works to create a corner in an air wall.
        They’ve included an exit, presumably because that’s the only way to meet fire regulations within budget.