• @Eheran
    link
    English
    61 year ago

    Flat line exactly until 100 °C? Unlikely.

    Looks more like there are only 5 points, connected with a line. But is the start correct (at 0 °C) or the point at 100 °C? Are the others points shifted too?

  • @psmgx
    link
    English
    21 year ago

    Explain

      • @[email protected]
        link
        fedilink
        English
        121 year ago

        It goes further than that. Young’s modulus does indeed determine the elasticity (springiness) of a material but don’t go ahead and think it’s only relevant for systems with moving parts that deform and go back into their original shape. Young’s modulus is literally at the very heart of every structural engineering calculation, static or dynamic.

        The stiffness of any structure is determined (among others) by E*I, I being the second moment of area determined by the shape of an object and E being Young’s modulus of the material. The tension in any structure is also determined (among others) by (load)/E*I. So Young’s is proportionally responsible for an objects ability to resist deformation under force and inversely proportional for the stress inflicted to the material by those forces. Both deflection and stress are potential causes for failure. If your structure loses a significant amount of its structural rigidity, it might fail. If the stress in parts of your structure rises significantly, they might fail.

        So steel may only melt at 1400C, but it has already lost half its load bearing capabilities at around 550C. Whether a structure collapses entirely is mostly a question of what factor of safety the engineers have applied when dimensioning the components. If the temperature was 550C (hypothetical, for this example) and the steel beams did indeed lose half of their ability to resist deformation by the loads they were bearing, and the tension in them did double, even a relatively high factor of safety of 2 ( i.e. everything is built twice as strong as it needs to be) would be the tipping point for catastrophic failure. In reality the factor of safety was probably lower, between 1.5 and 2.

        • @Revonult
          link
          English
          1
          edit-2
          8 months ago

          I dont think change in E alone can be used to 1-for-1 compared the change in Yeild/UTS. However, buckling is entirely determined by geometry and stiffness (E). Reducing E would drastically increase sustainability to buckling.

          Edit: stuff after.

          Okay so in you example structural steel around 500c is around half the strength, but its not always the case and does not directly correlate to E. For example at around 300c the strength increases.

          https://www.engineeringtoolbox.com/amp/metal-temperature-strength-d_1353.html