• @[email protected]
      link
      fedilink
      English
      1
      edit-2
      6 months ago

      Pretty sure they’re on 115/120v. Which is also not entirely true because part of the country is apparently wired for 230v or something.

      I dunno, there’s a long history there.

      • @[email protected]
        link
        fedilink
        English
        1
        edit-2
        6 months ago

        Japan is just 100V, not 110/115/120, there are some appliances that will use 200V. Similar to how the US has 240V. The weird bit with Japan uses both 50 and 60hz.

        • @[email protected]
          link
          fedilink
          English
          16 months ago

          Right. That was the thing. They’re 50/60hz based on location. I know something was different but I misremembered.

          For the US, they use 240v split phase. The secondary on the transformers have a middle tap, called neutral, so if you go from line to line, you get 240v, if you go from either line to neutral, you get 115/120v approximately. The benefit to it is that you can use two 120v devices in series, one connected to line 1, the other on line 2 and the neutral connections simply connected together. Total load voltage is 240v.

          But appliances that use a lot of current like clothes dryers, air conditioners/heat pumps, water heaters, and ovens, can be connected to 240v directly.

          It creates some interesting opportunities and challenges.