• @[email protected]
    link
    fedilink
    English
    1
    edit-2
    6 months ago

    Pretty sure they’re on 115/120v. Which is also not entirely true because part of the country is apparently wired for 230v or something.

    I dunno, there’s a long history there.

    • @[email protected]
      link
      fedilink
      English
      1
      edit-2
      6 months ago

      Japan is just 100V, not 110/115/120, there are some appliances that will use 200V. Similar to how the US has 240V. The weird bit with Japan uses both 50 and 60hz.

      • @[email protected]
        link
        fedilink
        English
        16 months ago

        Right. That was the thing. They’re 50/60hz based on location. I know something was different but I misremembered.

        For the US, they use 240v split phase. The secondary on the transformers have a middle tap, called neutral, so if you go from line to line, you get 240v, if you go from either line to neutral, you get 115/120v approximately. The benefit to it is that you can use two 120v devices in series, one connected to line 1, the other on line 2 and the neutral connections simply connected together. Total load voltage is 240v.

        But appliances that use a lot of current like clothes dryers, air conditioners/heat pumps, water heaters, and ovens, can be connected to 240v directly.

        It creates some interesting opportunities and challenges.