    That’s good then. Although I hope they also considered what happens if there’s two of them on a circuit, because if the mains power goes off, but there’s another panel on the same circuit, they’d each see the other’s voltage on the line, right?

    And yeah, you should verify that a circuit is de-energized after you flip the breaker, but I’ve seen both some real weird electrical work, and some electricians who aren’t that careful.

    • @DaBPunkt
      link
      English
      112 months ago

      They generate no frequency so the situation you fear is not possible.

      • @[email protected]
        link
        fedilink
        English
        52 months ago

        The panels themselves are DC, but there’s an inverter feeding 120V 60Hz (or whatever) into the wall, right?

        • @[email protected]OP
          link
          fedilink
          English
          16
          edit-2
          2 months ago

          Yes, but it’s a system that is designed to sync with the frequency of whatever other electricity is out there, and it shuts of if the main shuts off. Almost all rooftop systems without a battery in the US are set up the same way.

          Still, it’s important to check that things you think are disconnected do not have current flowing through them. And this makes it more important.

          • @laverabe
            link
            English
            12 months ago

            Pure sine wave or modified? Modified (square wave) are not good for electronics, particularly computers.

          • @Hedin
            link
            English
            -62 months ago

            deleted by creator

    • SkavarSharraddas
      link
      fedilink
      42 months ago

      Although I hope they also considered what happens if there’s two of them on a circuit

      The regulations allow only for one. If you want a bigger install than that you need individual approval I think.