• @lloydxmas
    link
    13
    edit-2
    2 months ago

    It’s on you. They’re talking about the 90 degree elbow behind the bong that heads upwards. It’s piped like it’s to a vent, but the location relative to the cabinet opening means the vent for the sink is… between you and the sink

    [edit] so their comment is saying “yea I see the bong, but that plumbing work is shit and I can’t get past it”

    • @Buddahriffic
      link
      3
      edit-2
      2 months ago

      Ah, yeah, I see that now, rereading what they originally said.

      Out of curiosity, what is the issue with using a vent 90 degree elbow vs whatever should be used there instead?

      Btw, I’m assuming that’s the drain pipe coming from the sink above rather than a vent, especially since it looks like the dishwasher drain is attached to the horizontal part… Wait, is it attached to the bottom of the horizontal section??

      Edit: looks like it’s sloping downwards the wrong way, too, if it is a drain pipe.

      • @[email protected]
        link
        fedilink
        English
        52 months ago

        Drains should always have a P-trap within so many inches of the drain opening. That prevents sewer gas from escaping from the drain. This is what should be there if it’s a sink drain.

        The issue with a vent 90/elbow in a sewer line is that they slow the water flow and can easily become obstructed. Normal elbows are curved to help prevent the water flow from slowing down.

        • @Buddahriffic
          link
          12 months ago

          Thanks for the info!

          Why does the p-trap need to be so close to the opening? As long as it’s somewhere along the line, shouldn’t it prevent gases from flowing? My own kitchen sink doesn’t have a p-trap in the cupboard below but I assume there’s one downstream because I’ve never noticed sewer smells in the kitchen. I figured it was the developers being cheap as soon as I noticed it, but they seem to at least have prevented the issue another way, so it’s hard to say if they were cheap or just efficient (or maybe neither if it’s just a p-trap in a different location).

          My bathroom sink does have a p-trap under the sink though, so I’m still confused as to why it’s done one way in one spot and another in the other.

          Only other guess I have at this point is it was done that way to simplify fitting the drain pipes under the sink because the hole for the pipe is directly underneath the one sink drain and it just feeds directly down via a vertical pipe, with the other sink’s drain feeding into that via a y-connection.

          • @[email protected]
            link
            fedilink
            English
            3
            edit-2
            2 months ago

            One problem with a “central” P-trap is that if it were done that way, you’re going to get nasty smells somewhere. Sewage frequently doesn’t make it out of your house as fast as you think it will and running water down the drain changes the air pressure in the drain line to varying degrees.

            The main reason it’s positioned so close to the drain opening is to accommodate venting. Every drain opening has to be vented, typically with a pipe going through the wall to a vent stack in the attic, to prevent the P-trap from being sucked dry when you do something like flush the toilet or run the clothes washer.

            Ever run the washing machine and hear a sink on the other side of the house gurgling during the drain cycle? That’s because the washer draining changes the air pressure in the sewer line and the sink isn’t properly vented causing air to bubble through the the P-trap.

            • @Buddahriffic
              link
              12 months ago

              Ok, I don’t ever hear gurgling from other drains, so whatever they did end up doing must be set up properly. There is what looks like a capped vent that ends just a bit above the cupboard floor, guessing it acts as a buffer for air pressure to allow it to fluctuate without venting the gases into my living space.

              • @[email protected]
                link
                fedilink
                English
                32 months ago

                Might be an air admittance valve. Those are usually used when venting to the roof isn’t possible or practical.

                Plumbing is one of those things that’s sort of an art. You can do a whole bunch of shit wrong and have it still technically function properly. Nobody will know except you and the next person who actually knows what they’re looking at.

                • @Buddahriffic
                  link
                  12 months ago

                  It’s surprising how much depth there is to plumbing. And alarming how easy it is to become overconfident that one has it mostly figured out.