Hi

A couple of days ago the hotend wouldn’t heat up and i got a couple of errorcodes/warnings in the display. The bed heats up just fine, so i ordered a new hotend parts (heater, thermistor and a new aluminum block). Changed all of this, but still the same error. I can se that the thermistor works because it changes values in the display when touching the thermistor-end. Any good ideas why the heater doesn’t heat?

  • @[email protected]OP
    link
    fedilink
    English
    25 months ago

    The thermistor temperature reacts to me touching the thermistor-end. This shows in the display- So i believe this is not the problem here…

    • @[email protected]
      link
      fedilink
      English
      25 months ago

      Fair, a wire break can be annoying though, often they’re intermittent, and the display often doesn’t respond fast enough to show that, but thermal protection will.

      I’d totally consider taking a look at the connectors to the board for the heater cartridge, see if there’s good contact being made, check for any signs of things like scorching check end-end continuity. Looking at the schematics for that mainboard Btt skr 1.4 it looks like there are LEDs on all of the MOSFETs, it will give you a visual indicator of the board state, to help narrow down your troubleshooting.

      • @[email protected]OP
        link
        fedilink
        English
        15 months ago

        Thanks for the links. Can’t see any scorching, and everything I’ve measured seems OK. If there are LED’s on the mainboard, i don’t know how to light them. As of now there are no lights on the motherboard, but everything beyond that heater works…