The researchers also say that current fire-resisting gels dry out and become useless about 45 minutes after being applied. With their new material however, because the silica aerogel stays behind until it is washed away, the coating could be applied well in advance of an approaching wildfire while still providing protection when the flames arrive

  • Andy
    link
    fedilink
    English
    226 days ago

    I’m concerned that this would require a continuous supply of water at a flow rate that might not be realistic.

    • @A_A
      link
      English
      226 days ago

      Water flow is only required when the fire (wildfire) is near

    • Not a replicant
      link
      English
      226 days ago

      I’ve got a fire suppression system. An agricultural sprinkler on each of the two roof peaks, fed by a pump from storage tanks. We’re off-grid (no mains) and already have the storage tanks - 2 x 22500litre/5000 gallons. With full tanks, the sprinklers should operate for ~7 hours, which is way more than necessary - three to four hours would be enough. The sprinklers “throw” interlocking circles of water, they intersect over the roof and saturate all the ground and foliage out to about 15 metres/50 feet. Water falling on the roof goes back into the tanks. The pump is electric, but being off-grd, we’ve got big batteries and a backup generator, so I’m confident the pump would run long enough for the fire to pass.

      • Andy
        link
        fedilink
        English
        126 days ago

        That sounds like some very cool engineering. I hope it sees as little use as possible, but I’m glad you’re prepared.