I have a somewhat interesting issue.

Recently I’ve installed the BTT SFS v2 filament sensor, which detects both if filament is present and if there is a jam or not. The jam detection works with an encoder that spins whenever filament is running through it.

Pressure advance however works by slowing down and speeding up extrusion based on motion of the nozzle to prevent bulging and oozing.

This however triggers false positives in the jam detection. Without pressure advance it works fine.

Does anyone have experience with this? Below is example code of my Klipper config related to the jam sensor. Raising the detection length from 2.88 to 10 did not solve it and I don’t want to put excessive numbers there.

[filament_motion_sensor encoder_sensor]
switch_pin: i forgot lol
detection_length: 10
extruder: extruder
pause_on_runout: False
runout_gcode:
  PAUSE # [pause_resume] is required in printer.cfg
  M117 Filament encoder runout
#insert_gcode:
  #M117 Filament encoder inserted
  • roofuskit
    link
    fedilink
    English
    arrow-up
    4
    ·
    13 days ago

    PA isn’t the issue. Klipper compares the rotation of the sensor to that of the extruder. It’s when one is moving and the other isn’t that’s the issue. You probably need to tweak a setting. I had to bump the filament distance up on mine.

      • Bluewing
        link
        fedilink
        English
        arrow-up
        2
        ·
        12 days ago

        Oh, I did that once. Misplaced the decimal on the PA. It took me far longer to figure it out than I care to admit.