• @Mostly_Gristle
    link
    126 months ago

    Nah, I hired an electrician to handle all that for me. Now if I want electricity all I have to do is stick a plug in a socket, or flip a switch. It’s way more convenient.

    • @[email protected]
      link
      fedilink
      46 months ago

      If the power into your house is off from 60Hz (or 50 depending on your region), an electrician isn’t going to do diddly.

      • @datelmd5sum
        link
        26 months ago

        How could it be off frequecy at house level? Aren’t the generators at the powerplants being spun at 50 or 60 times a second?

        • @[email protected]
          link
          fedilink
          26 months ago

          Not exactly. There’s a ratio of RPMs of the drive motor to the specific input of the alternator that generates the correct frequency. It depends on the way the alternator is designed (ie number of poles) that will yield the correct frequency, almost like a gear ratio, that is optimized for efficiency, and power plants have to constantly make slight adjustments to the drive motor speed the keep the frequency exact (usually done automatically within the drive control system).

          I’ve never seen frequency be an issue in a residential system, but in theory it could happen.

          • @[email protected]
            link
            fedilink
            2
            edit-2
            6 months ago

            It used to be common for clocks to be driven directly off the electrical frequency. The US Navel Observatory would call up generator plants and tell them to slow down or speed up a little to make a correction to all the clocks. I’m not sure if that still happens, though.

            • @[email protected]
              link
              fedilink
              16 months ago

              I’ve heard that trope before, same reason clocks in US schools/govt institutions were always plugged into a wall, hence these. Nowadays, NTP has rendered that obsolete.

          • @datelmd5sum
            link
            16 months ago

            I don’t know how it’s in 60Hz regions, but here the generators are in 3 phases, 120 degrees apart. The voltage gets transformed to up to 400kV, still in 3 phases, and then down to 400V when it’s distributed to peoples’ homes. Then you can pull 400V 3-phase or 230V 1-phase from your wall.

            • @[email protected]
              link
              fedilink
              16 months ago

              It’s the same here, though we have varying degrees of transmission and distribution voltages via transformers and regulators. In my area, power comes into our valley from the 500kv lines through the open desert, into the valley at 33kv, and stepped down to 5kv for neighborhood distribution that the single phase 240/120v transformers tap off for the EOL.

              More of what I was getting at was that generation is more or less the same across regions. Some external fuel source (whether it’s diesel, natural gas, nuclear, steam, etc) does its thing to drive a rotor that’s connected into an alternator which is essentially an electric motor but instead of the electric motor doing the driving, it’s being driven which generates power, and the RPMs of whatever given fueled drive mechanism are not necessarily 1:1 with the alternator speed.

        • @[email protected]
          link
          fedilink
          English
          16 months ago

          My understanding is that if electrical demand starts outstripping supply the sinewave can start getting badly mishapen.

          From watching videos about synthesizers and playing with VCV Rack I’ve learned far more about waveforms than I ever did from any electrical education or research