    IR thermometers aren’t particularly accurate. Especially when pointed at reflective surfaces like glass, where some of the return will actually be reflected heat coming from you.

    Most wall thermostats are designed to read the temperature of the air; the wall behind may be warmer or colder.

    • osaerisxero
      link
      fedilink
      721 hours ago

      Most wall thermostats are designed to read the temperature of the air; the wall behind may be warmer or colder.

      This is correct. Specifically for the honeywells, they have little holes to measure air temperature usually on the top or bottom depending on model. The smart ones (like this one is) can also be manually calibrated up or down from what their internal thermostat says if there’s a known deviation (i.e. the wall is consistently putting off enough heat to throw off the stat).

      • @Omgpwnies
        link
        English
        117 hours ago

        Also the electronics in the thermostat might be generating juuuust enough heat to make a difference depending on where the IR thermometer is pointing

    • @[email protected]
      link
      fedilink
      English
      822 hours ago

      This is why it’s important to get one with an adjustable emissivity, so you can adjust it to whatever material you are measuring. Or you can stick some electrical tape on what you want to measure, 3M super 88 is 0.96 so I just set my fluke to 0.96 and stick that shit everywhere I want to measure.

      • @lemming741
        link
        English
        319 hours ago

        But 88 is trash my dude
        I’m a 33 man

      • @TrickDacy
        link
        220 hours ago

        Why is this joke downvoted? It would make no sense to take this at face value unless we assume you are extremely mentally ill

  • @[email protected]
    link
    fedilink
    English
    2220 hours ago

    A man with one clock knows what time it is with certainty. A man with two clocks is never sure

  • @[email protected]
    link
    fedilink
    1219 hours ago

    Only 1.6° difference that’s probably within tolerance especially when it’s not calibrated after leaving the factory.

    • @[email protected]
      link
      fedilink
      English
      818 hours ago

      Yeah I have one of these infrared thermometers. The tolerance is within 1°C. They aren’t designed for precision but for “is this thing at a temperature that I expect”.

      • @stevestevesteve
        link
        217 hours ago

        That’s assuming you’ve got the emissivity set correctly, too. Can make a huge difference

  • @TrickDacy
    link
    1120 hours ago

    Woah you mean every thermometer isn’t perfectly accurate??

  • @Mike85k
    link
    622 hours ago

    Point it at the wall right next to it and see. I’ve noticed this on mine but it will match with the wall. The reflective comment could be. I’ve always assumed that it has to account for the slight heat that the thermostat generated just by running. My experience is with an ecobee smart thermostat so probably generate a a bit more heat.

    • elmicha
      link
      fedilink
      121 hours ago

      I have an IR camera adapter and pointed it at a computer fan. I was astonished that the motor in the middle was warmer than the blades, although the fan was off for a long time. Then I saw that it measured the reflection of my head in the name plate.

  • @Agent641
    link
    622 hours ago

    Thermostat is displaying bullshit? Always has been.

  • @But_my_mom_says_im_cool
    link
    321 hours ago

    The thermostat reads the temp in its immediate area, and many times it’s mounted on the wall where the heating or cooling vent is located. This is why your thermostat reads one temperature but your room across the apartment feels colder.