About 2-3 years ago the line clogged and I didn’t catch it for a while and we had some serious water damage. It just clogged again and I caught it pretty quick but it could have been bad.

Shop vac solves the immediate problem but I’d like a more permanent solution. Any ideas?

  • @esc27
    link
    101 year ago

    My drain has a float switch. If the line clogs and water backs up, it turns off the unit. I also have a leak sensor in the pan that integrates with my security system.

    A permanent fix would be a larger drain or a backup drain.

    • @TandybaumOP
      link
      21 year ago

      My shit is pretty old and there isn’t a float switch. We’re planning on a full replacement next year so maybe this is the answer.

      • @[email protected]
        link
        fedilink
        English
        31 year ago

        Water sensors are a cheap investment that can be reused later. You can also buy inexpensive ones from Tuya or Aqara that are smart and should be able to notify you on your phone over just a simple one that beeps.

        • @[email protected]
          link
          fedilink
          11 year ago

          And if the unit plugs into an outlet there are smart adapters than can cut off power at a signal from the security system.

      • themeatbridge
        link
        31 year ago

        A float switch is cheap and easy to install, but I would hire a pro to do it.

  • @[email protected]
    link
    fedilink
    101 year ago

    I live in Florida, I keep two things on hand for my HVAC drain line. First is condensate cleaner (less harmful to the plastic than bleach) which I use monthly and my backup is a Gallo Drain Gun. Even on my worst blockages, 2 shots of the drain gun cleared it out.

    • @TandybaumOP
      link
      2
      edit-2
      1 year ago

      condensate cleaner (less harmful to the plastic than bleach)

      Do you have a brand or version (looks like there is liquid and tablet) you’d recommend? I think it’s a good idea to start with this monthly.

      • @Bdtrngl
        link
        41 year ago

        I had a blockage that left puddles in my basement when were running the ac a lot during July. A couple of the blue ac safe tablets took care of it.

      • @[email protected]
        link
        fedilink
        21 year ago

        Can’t say I’ve seen much difference, In my case, there is a place inline in the drain tube to pour in liquid so I use Algaecide in that but if you don’t, use the drain pan tablets – no idea which would work better though. It does work best as a preventative before you get buildup. My drain line is long with many twists and turns, lots of places ideal for buildup (I curse the builder for this!)

  • clif
    link
    71 year ago

    Not exactly a “fix”, but a water alarm can ensure an overflow doesn’t go unnoticed… but then you’ve got a battery to remember.

    That said, the ones I have under my sink and near my water heater have been running on the original 9v battery for over 8 years now

    • @TandybaumOP
      link
      41 year ago

      I actually have one but it’s sitting in the water heater pan 1 foot away… I’ll get a second one right now.

  • Mbourgon everywhere
    link
    61 year ago

    Pour bleach down the tube once a month. There’s usually an opening for it.

    • @TandybaumOP
      link
      41 year ago

      There is an opening… I might start this. Change the filters and feed it some bleach

      • Mbourgon everywhere
        link
        51 year ago

        My AC guy said that it prevents the sludge that’s trying to grow in the drain, from blocking it. Set a calendar reminder and do it once a month.

      • @nukeworker10
        link
        31 year ago

        Just a little, like half a cap, is all you need.

  • @[email protected]
    link
    fedilink
    51 year ago

    Do maintenance on the air filters. The water is being condensed straight from the air so it’s not hard water or anything. The only explanation is that enough dust is settling in the water that it clogs the drain. There must be some kind of air filter upstream of where dust can collect in the water line, and that air filter probably needs replacing.

    • @[email protected]
      link
      fedilink
      English
      1
      edit-2
      1 year ago

      The cheaper/lower quality the air filter, the less particulates it filters from the air. What dust the filter doesn’t catch cycles through the system and can get caught by the AC coil. Filter effectiveness is measured by its MERV rating. The higher the rating, the more particulates it will catch. I use a MERV 13 filter but that’s because I’m alergic to the entire planet and it helps reduce airborne allergens. If you go much higher than that your furnace/air handler may struggle to blow air.

  • @[email protected]
    link
    fedilink
    English
    31 year ago

    What’s causing the clog?

    I’m assuming this is a split unit? I don’t have one, but I thought there was a float protection to prevent the AC from running if there was too mich water in it. Of course, this would probably only work if the clog was near the unit itself.

    • @TandybaumOP
      link
      21 year ago

      What’s causing the clog?

      The clog is “gunk” but I’m not sure what is actually causing it.

      When I hit it with the shop vac I can hear it clearing a blockage of MISC gunk.

      • @[email protected]
        link
        fedilink
        English
        41 year ago

        “Gunk” is probably a combination of algae sludge plus any captured lint from the ventilation. Not much to do about the algae other than blast it with a disinfectant like bleach once in a while.

        How’s the incoming air filtration into the unit? Is it sealed reasonably well at the filter?

        • @TandybaumOP
          link
          21 year ago

          Pretty good other than I could probably be a little more diligent with my filter changes. I do it monthly(ish)

          • @[email protected]
            link
            fedilink
            English
            11 year ago

            Ah yeah, then a little bleach when you do your monthly maintenance will probably help that drain out a lot.

  • Endorkend
    link
    fedilink
    21 year ago

    Preventative maintenance.

    As you said, takes years to go bad.

    So take the 10-15 minutes of time it takes to clean the duct, once a year.

    And start making a list of things you can do preventative maintenance on.

  • @surewhynotlem
    link
    11 year ago

    If you can’t put in a float switch, a drain snake once a month should keep it clean.

  • @Hazdaz
    link
    01 year ago

    I have a similar issue. My line is coming from the 2nd floor and there is a pipe in the wall that drains outside newr ground level. The pipe is probably 12 foot long and takes a few bends.

    I used a snake to clear the line a few weeks ago. Not entire sure what exactly is causing the clog but like you said, it’s probably just gunk.

    Now after I cleared the line I was ready to pull the drain out, but the pipe is like 1/2" so the snake isn’t really blocking any condensate from dripping down. So for the last few weeks, I’ve simply left the snake in there. I’m thinking with the snake in there either maybe the gunk won’t grow to clog the line so easily, or since it’s already in there, all I have to do is wiggle the snake once a month and dislodge anything that might be starting to grow.

    The reason I don’t pull it out is because with the angle and bends in the pipe, I had a hell of a time snaking the snake up there. But once it was up there dislodged the gunk took all of 5 seconds.

    The snake looks to be regular steel which will rust with water touching it, so I’ve ordered some stainless steel wire which I will run up the pipe ans just leave it there. It’s not the beat solution but I don’t have access to the source of the condensate so I have to work backwards from the drain up.