• atocci@kbin.socialOP
    link
    fedilink
    arrow-up
    13
    ·
    1 year ago

    After trying as many suggestions as I could, it seems the one that did the trick was replacing the thermistor entirely. Seems I must have broken it somehow, though the glass bulb and wires were still intact from what I could tell.

    • kek_w_lol@lemmy.one
      link
      fedilink
      English
      arrow-up
      6
      ·
      1 year ago

      Glass bead thermistors have very fragile wires and sometimes you can’t see a break that has occured. I replaced mine with a cartridge as fast as possible, but good on you for finding and solving the problem.

  • evidences
    link
    fedilink
    English
    arrow-up
    7
    ·
    1 year ago

    Next step do a PID tune, that looks fixed but your hotend graph should be way flatter than that with a new PID tune.

    • atocci@kbin.socialOP
      link
      fedilink
      arrow-up
      2
      ·
      1 year ago

      How flat should I expect it to get? It’s sticking to +/-0.2° of the set temperature at the moment

      • evidences
        link
        fedilink
        English
        arrow-up
        2
        ·
        1 year ago

        Ok that fine then, thought that was more then it is.