Hi

A couple of days ago the hotend wouldn’t heat up and i got a couple of errorcodes/warnings in the display. The bed heats up just fine, so i ordered a new hotend parts (heater, thermistor and a new aluminum block). Changed all of this, but still the same error. I can se that the thermistor works because it changes values in the display when touching the thermistor-end. Any good ideas why the heater doesn’t heat?

  • @papalonian
    link
    English
    24 months ago

    I can se that the thermistor works because it changes values in the display when touching the thermistor-end.

    Good information. You can probably remove thermistor from possible cause, but to be sure, you can tape the thermistor to your heat bed, and heat to a high temp, make sure that the “nozzle” temp is close to the bed temp

    What is the behavior when you hear the nozzle? Does it immediately give error, or does it take some time? If it takes some time, is the temp changing on the nozzle at all, or it stays the same until error?

    • @[email protected]OP
      link
      fedilink
      English
      14 months ago

      When starting the preheat both the bed and the nozzle temperature starts at about 25c. There is no heating at all. The printer takes about 10-15 sec to conclude with the error message.