Household vehicles were driven an average of 64.6 minutes on a typical day in 2022 (including all trips made that day) and parked for the remainder of the time (95%). Drivers in all Metropolitan Statistical Areas (MSAs) averaged between 61 minutes and 68 minutes per day with the longest driving time of 67.6 minutes for those in MSAs with 1-3 million people. Household vehicles being parked for 95% of a 24-hour day offers opportunity for EV charging.

  • @NotMyOldRedditName
    link
    1
    edit-2
    3 months ago

    Switching to a NEMA 5-20 is easier and most modern houses are already wired to support it with no changes other than the plug which is a 5 minute job. (Don’t just assume you’re okay though, get it checked out) you also don’t give up what might be your only accessible plug for 120v things.

    That’ll take you from 7kmh to 11/12kmh which doesn’t seem like much but is actually quite a lot when the average commute in the USA is already less than what a 5-15 will do. Easily an extra 50km a day if its parked after work. The 5-20 also makes it more capable during the winter months.

    I have a small commute into town and have been fine on a regular 120v plug the entire time.

    The only time it’s annoying is when we come home from a road trip and we didn’t charge longer to get home with more. Then it takes days to build up (which is fine our commute is small) but for emergency situations I’d kinda rather have it be higher faster.

    Edit: all that being said though… efficiency wise 120v takes a hit and $ per kw/h you are paying more to use 120v

    • partial_accumen
      link
      13 months ago

      Switching to a NEMA 5-20 is easier and most modern houses are already wired to support it with no changes other than the plug which is a 5 minute job.

      A 20A circuit would require 12AWG wire (yellow romex) to maintain code in the USA and Canada. I can’t say I see that as common garage wiring in the houses I’ve seen. Most have 14AWG (white romex) which would limit it to 15A outlet (120v or 240v are both fine though).

      • @NotMyOldRedditName
        link
        1
        edit-2
        3 months ago

        Are those modern or older?

        I was under the impression it was standard now? Maybe Canada vs US difference?

        Edit: not standard as in code, just that it’s what usually happens now.

        • partial_accumen
          link
          13 months ago

          My house was built in the last 15 years and has white romex (14AWG) to the garage outlets. I don’t know about a house built brand new today.

          • @NotMyOldRedditName
            link
            13 months ago

            Well I might be wrong then, I thought 15 years would definitely be like that.