Tesla is facing issues with the bare metal construction of the Cybertruck, which Elon Musk warned was as tricky to do as making Lego bricks

  • @[email protected]
    link
    fedilink
    English
    41 year ago

    Eh, if someone tells me to reduce a tolerance from 5 to 10 thou at work, it’s understood that it’s +/-5 and 10. I don’t think I’ve ever heard someone use the full range of a tolerance in conversation. If the tolerance isn’t bilateral, it would be said like plus 5, minus zero. Anyways, +/- .0005" is our standard tolerance on the span of all dowel hole pairs.

    • @curiousPJ
      link
      English
      2
      edit-2
      1 year ago

      Bilateral tolerancing is a Machinist’s first introduction to tolerancing so it’s no surprise to run that as default. And I suppose GD&T is not heavily used where you are.

      If you’re given a parallelism tolerance of 10 micron are you assuming that to be ±10 micron? True position? Angularity of 5 thou? Etc… The only feature control that could be interpreted as bilateral by default is profile and it’s still communicated by its total tolerance.

      Simple ± tolerancing isn’t the industry standard anymore. And if Tesla prints are anything like spaceX ones… It’s basically all GD&T and minimal title block tolerances.

      • @[email protected]
        link
        fedilink
        English
        11 year ago

        I use GD&T on all my drawings, including 100% of my hole callouts. However I’m one of the more enthusiastic adopters of ASME Y14.5 at the place I work. Therefore, I get what your saying regarding the tolerance range, but since most of my coworkers are still relying on block tolerances, I’ll refer to a .010" positional tolerance as a “+/- .005” equivalent" in conversation so there is no miscommunication. I can see how this is not the norm.

      • @curiousPJ
        link
        English
        11 year ago

        Just curious… what does Starrett have that Tesla will need?

        Starrett isn’t known for quality precision metrology.