I’ve tried to report the issue to Prusa support but they keeps trying to diagnose it as user error. But at this point I’m at a loss and presume that it’s either a firmware issue or a sensor issue on my unit.

Either way im very disappointed.

And before you ask, this is the opposite side

PXL_20240301_160413072

EDIT: I will note that this print sheet is ruined for my use case, since those patterns will be shown on the underside of my prints. But the print surface still works and can be used without issue… if you ignore the gouges that are being detailed into every print.

  • @papalonian
    link
    English
    149 months ago

    Shouldn’t you make your adjustments while the bed and nozzle are at least partially heated, since metal expands when heated? If you adjust z-offset when cold, the nozzle may expand a bit, decreasing the gap. At least that’s my understanding, and why most printers I’ve seen will preheat the bed and nozzle before doing bed leveling

    • @SzethFriendOfNimi
      link
      English
      29 months ago

      If you’re using something like a tap or anything that uses the nozzle as the probe then you do want the bed and nozzle to be at temp (or close) so any thermal expansion is included.

      Same applies if you’re using something like auto Z offset (since it’s going to be hit with the probe AND nozzle)

      If you’re using something like a Klicky or BL touch then you need the bed to be temp but the nozzle doesn’t matter since you’re measuring with the probe. But… you do want the nozzle to be at temp when calibrating the Z offset so the right figure is used.

      Personally… I have a Klicky (Klackender actually) and heat the bed and then dial in the zoffset with a print and baby stepping