Did a bit of rewiring to remove a bypass to an old light socket with exposed live pre-romex wiring. Probably left a few of my own no-nos for future home owners. Forgot to take pictures of the old wiring, but maybe thats for the best, it had been running a freezer for many years. You could just touch it at any time and zap yourself.

  • Denvil@piefed.world
    link
    fedilink
    English
    arrow-up
    16
    arrow-down
    1
    ·
    3 days ago

    If this is on a 20 amp breaker, this is a massive fire hazard mixing different wire gauges

    If this is on a 15 amp breaker, then you’re fine

  • Bell
    link
    fedilink
    arrow-up
    12
    ·
    3 days ago

    If you solved a shocking outlet then that’s the most important & dangerous thing put to bed. Kudos & good job. Next time it doesn’t have to be an outdoor box, a cheap handy box would have worked. Also if your circuit has yellow (20 amp) Romex then all of it should be 20 amp wire. I just had to fix this very thing in a remodel where I added a couple of outlets. Inspectors jump on stuff like this but you’re home free…well until you sell

    • Elting@piefed.socialOP
      link
      fedilink
      English
      arrow-up
      10
      ·
      3 days ago

      It’s a 15A breaker, I had yellow and didn’t want to go buy a spool of white for this little bit.

  • BCsven@lemmy.ca
    link
    fedilink
    arrow-up
    4
    ·
    3 days ago

    So why does the electric receptacle have two wires to it, are you feeding another receptacle or something from it?

    • Noel_Skum@sh.itjust.works
      link
      fedilink
      arrow-up
      1
      ·
      3 days ago

      I could not even understand the question you were asking until I did a quick web search…

      TIL that the US doesn’t (often) use ring mains / ring circuits for domestic power point installations.

      I didn’t know radial circuits were still a thing.

      • BCsven@lemmy.ca
        link
        fedilink
        arrow-up
        2
        ·
        3 days ago

        You must be in the UK?

        Yeah in Canada and US the room size on most homes is large and we require a receptacle every 12 feet I think, so rather than a junction that spiders out to say 8 run receptacles that would require a lot of wire, we wire from receptacle to next one. So you are just doing 12 foot jumpers to each rather than say 30 foot individual from a ceiling junction down to each wall location.

        There’s probably pros and cons to each style.

  • Fizz@lemmy.nz
    link
    fedilink
    arrow-up
    1
    ·
    3 days ago

    My brain is cooked. I thought that first lightbulb pick was some homemade flashlight device before a lightbulb